Are your fire doors up to standard?

Are your fire doors up to standard?

Image of Fire Door safety week

Fire doors are an  important part of fire safety they save lives and property. They provide important protection within buildings such as protecting escape routes in staircases and corridors and making sure that smoke and fire are contained enough for people to escape.

Important facts about fire doors

  • Fire doors must work correctly to save lives
  • Fire doors must be fitted with the correct components suited to the door leaf and its purpose.
  • They should be maintained and installed by competent people.
  • Correct glazing and ironmongery must be used on fire doors
  • Alterations and adaptions must never be done whilst onsite.
  • A fire door’s performance should never be compromised
  • A Fire should never be wedged or propped open
  • Fire doors must be third party certified to BS 476 Part 22 or BS EN 1634 Part 1
  • Correct frames should always be used.
  • Intumescent strips should always be used.

 

 

Below is a video of how fire doors should be fitted and what happens when they are not!

 

DO’S & DON’TS

DO

  • Specify and use third-party certified fire doors and components
  • Buy fire doors, frames and components from certified companies
  • Check the certificate matches the door
  • Make sure you have the correct certification for the door’s intended use
  • Install and maintain fire doors using competent personnel
  • Make sure that ironmongery components are CE marked

 DON’T

  • Fit a fire door like any other door – it’s not, it’s an engineered safety device
  • Cut vision panels and other holes on site
  • Patch up a fire door
  • Take risks by reducing the specification
  • Disconnect a fire door closer
  • Prop or wedge open a fire door

 

Some Images Of Dodgy Fire Doors

Below is a video of how installing a fire door is NOT the same as installing normal doors.

I have experienced this first hand when I carried out a fire risk assessment on a property of a client of mine.  They used a construction company who have either never installed fire doors or have no idea how to,  as the gaps between the leaf and frame were well above 3mm,  they had cut too much off the doors, a lot of the doors wouldn’t close under there own weight plus there were only two hinges installed. The owner wasn’t very happy with this especially when I told him that all the fire doors need to rectified which undoubtedly meant replacement.

If you would like more information about fire doors please click here.